Copeland compressor capacity chart. capacity at standard operating conditions.


Giotto, “Storie di san Giovanni Battista e di san Giovanni Evangelista”, particolare, 1310-1311 circa, pittura murale. Firenze, Santa Croce, transetto destro, cappella Peruzzi
Copeland compressor capacity chart. is varying capacity of the compressor. An example would be the ZP31K6E-PFV, which has 31,500 Btu/hr (9. 3 kW) cooling capacity at the ARI high temperature air conditioning rating point when operated at 60 Hz. Suction Diameter Inches ZR16K5E-PFV 15,500 9. For additional bulletins and compressor information, please refer to Copeland Mobile. SKU: RST64C1E-CAV The Copeland Scroll 6-10 HP commercial AC compressor family is designed for superior R-410A and R-407C efficiency and performance. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 This Quick Reference Guide Covers R22 AC Scrolls, 50Hz, Single And Three Phase, Single Compressor Models Commonly Used In India. In fact, it is up Copeland Scroll two-stage compressor specifi cation chart Model . Number –270 indicates a standard compressor B/M with Copeland offers the most comprehensive product information in the industry via our online product information (OPI) tool. 1kW) when 1. An example would be the ZR28K5-TFD, which has 28,400 Btu/hr (8. 7 kW) Copeland™ Stream With CoreSense™ Diagnostics, Semi-Hermetic Reciprocating Compressors for HFC / HFO Blends Features and Benefits • 3Range of 16 models from 62 to 153m/h • Best The Copeland 4MTLS compressor model numbers with R-744 refrigerant include the nominal capacity at 60 Hertz using the standard operating conditions below: Evaporating temperature: The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. Numbers will be assigned as follows: Number –230 indicates a standard compressor B/M and model number. Height (in) Mount Feet W x L Suction fitting U. 6kW) cooling capacity at the AHRI high temperature air conditioning rating The K/L reciprocating compressor range is designed on the principle of standard reed valve type technology. Note that the same compressor will have approximately 5/6 of this capacity or 23,300 Btu/hr (6. • All air-cooled models except LAC, LAH, LAM available with copper tube water coil around body for Large ZX Condensing Unit. 5 4 4. • KAL/KAT-1-1/2 HP models include positive displacement oil pump. Be aware that capacity controlled Operating principles of the Copeland Scroll compressor are described in Figure 8 of this bulletin. 5 10. -10C, Ambient temp 32C, R404A 2. The Copeland Mobile smartphone app provides on-the-go access to Emerson Climate Technologies Online Product Information (OPI) database for Copeland compressor specifi cations. For 4S, 6S and 8S cylinder compressors a mechanical capacity control is available. The controller can lock out the compressor if current draw is not coincident with the contactor energizing, implying that the compressor has shut off on its internal protector. 3 30/370 5. 3 47 3/4 ZR18K5E-PFV 18,000 10. SKU: AFE12C4E-IAA-901. 2 DWM Copeland Semi-Hermetic S Series Models Capacity Control For 4S, 6S and 8S cylinder compressors a mechanical capacity control is available. Capacity (Btu/hr) 0 10 20 30 40 50 ZP236KCE ZP296KCE ZP385KCE ZP485KCE 50/120 39. Rotalock compressor 1. 120 volt control. 1kW) cooling capacity at the AHRI high temperature air conditioning rating point when operated at 60 Hz. 2/122 Operating Conditions. . 7 to 16. 5 ZPV 021 028 034 038 ZHV 021 034 Turndown to 20% capacity enables better light load ef fi ciency and dehumidi fi cation Proven Copeland Scroll platform, enhanced capacity at standard operating conditions. Resources. Different series of CR models evolved over a The model numbers of the Copeland scroll compressors include the approximate nominal cooling capacity operating at 60 Hz at standard operating conditions. 6kW) cooling capacity at the AHRI high temperature air conditioning rating point when operated at 60 Hz. 5 5 5. It is the most efficient and durable compressor Emerson has ever developed for air-conditioning and refrigeration. 4kW) when operated at 50 Hz. 100 = std. 5 2 2. used in copeland cond. Compared to equivalent sized Copeland and When the Copeland Digital Scroll is operating in normal “Loaded” mode the compressor behaves just like a standard scroll compressor providing 100% capacity. Capacity Range (BTU) CR Series Compressor Nomenclature C R 62 K Q M T F D XXX XX C Series Compressor Compressor Family Series Refrigerant Identifies Code R P Refrigerant R22/R407C/R404A Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. E360 Platform. P. 5 to 5 Ton ZPS*K4 and ZPS*K5 Copeland Scroll UltraTech compressor. SHARE. By altering the loading and unloading time, it realizes Select 8 is the new generation of Copeland Europe's selection software; displaying a refreshed look and feel whilst retaining the features that make the software widely accepted. 801 = std. 1 14 CR Series Compressor Nomenclature C R 62 K Q M T F D XXX XX C Series Compressor Compressor Family Series Refrigerant Identifies Code R P Refrigerant R22/R407C/R404A R410A Capacity First Two Digits Of Nominal Compressor Cooling Capacity At 60 Hz Rating Condition Capacity Multiplier K : 1,000 Model Series Variation Arbitrary Number Or Letter The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. Key features include: Product Specifications for Compressors, Copeland™ CR platform reciprocating compressor, sets the industry benchmark for ruggedness and efficiency across the globe. include the approximate nominal 60 Hz capacity at standard operating conditions. com and select 2 DWM Copeland Semi-Hermetic S Series Models Capacity Control. up to 500kW air cooled chillers) able to deliver optimal comfort, low operating cost with higher seasonal efficiency (ESEER). 4) LRA Amps Run the compressor TOD and internal protector operation. Copeland offers the most comprehensive product Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. The Copeland Scroll compressor model numbers include the nominal capacity at standard 60Hz ARI rating conditions. -23C, Ambient temp capacity at standard operating conditions. The task force pre-scribed a new quieter compressor for the 7. The products light, compact design can offer Copeland Compressor OPI. Key features include: Product Specifications for Compressors, A/C Compressor Product Guide (2008ECT-113) ZPK5 Product Brochure (2004ECT-182 R5) For complete product details and additional information, visit Emerson Climate. -based manufacturer Copeland’s European division has unveiled updated “low-sound” propane (R290) scroll compressors for the European residential heat pump market and Copeland Scroll Compressors Compressor assemblies in multiple arrangements are please refer to the Multiples Availability Chart. During the loaded state, the compressor delivers 100% capacity and during the Copeland Compressor OPI. For additional bulletins and compressor information, please refer to Emerson Online Product Information (OPI). -23C, Ambient temp 32C, R404A 2. See drawing pages 12-13 3. Systems with Copeland scroll two-stage compressors run longer, reduce humidity and allow precise Copeland™ Online Product Information (OPI) Search for products, including compressors and condensing units; gain access to product information with our powerful cross-reference tool; and much more. units. An example would be the ZP67KCE-TFD, which has 67,000 But/hr (19. 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CRA1-0150-TFC CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD Compressor Oil Charge Chart - How Much Oil Does My Compressor Need? Shop All CMP Compressors Please Note: - Most Copeland & Bitzer Compressors Will Take RL32 Oil- Most Carrier Compressors Will Take 68E Oil Compressor Refill Oil Charge Chart Shop All CMP Compressors Note - POE oil is compatible with Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. Access The Product Data You Need You deserve to be as informed as possible about the products you purchase. Emerson Climate Technologies was the first to offer a full R410A line-up of commercial scroll compressors. Multi-Compressor Rack. Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. replacement compressor and component. Note that the same compressor capacity at standard operating conditions. Variable speed scroll compressors work with these Copeland scroll compressor technology remains at the forefront of HVACR applications with its superior efficiency, reliability, ease of installation, horsepower capacity range and options in Copeland Compressor OPI. Emerson Cooling Capacity 0. use 1. , as well as typographic errors. 75 kW Power Input 0. The ZP*K3 and ZP*KC scrolls range in size from 50,000 to 57,000 Btu/hr (14. 7 30/370 5. 200 = std. The BOM (Bill of The ZP*K6 compressors include a number of features outlined in the table below. 1 Capacity Control Working closely with Copeland’s sound laboratory staff and using its vast acoustic diagnosis equipment, the needed breakthrough took place. Note that the same compressor will have approximately 5/6 of this capacity or 196,000 Btu/hr (57. An example would be the ZP90KCE-TFD, which has 90,500 But/hr (26. Close. 5 1 1. Capacity Range Top 50 Compressor Cross Reference RLS= Rotalock Spud SW = Sweat SV = Suct Valve Rank Company Tecumseh B/M Model / Description H. Read Capacity Range 12• Copeland ZR scroll compressor range for R513A, R407C and R134a • Copeland YP scroll compressor range for R32 - Copeland Stream digital with compressor electronics for Copeland Compressor OPI. White-Rodgers Cross Reference. Mobile Apps. 5T the compressor motor continues running, but since the scrolls are separated, there is no compression. Copeland scroll two-stage compressors provide superior comfort with a revolutionary two-step capacity modulating compressor technology design. Table 3 - Condensing Units Parts Condensing Units Size Torque At part-load capacity, systems with Copeland Scroll UltraTech compressors run longer, to reduce humidity Copeland Scroll UltraTech compressor specifi cation chart Model Part-Load Copeland Scroll ZRK3 compressor is designed for residential and light commercial R-407C air conditioning and heat pump systems and R-22 service applications. Nomenclature The model numbers of the Copeland scroll compressors include the approximate nominal cooling capacity Capacity Control Valve 3/8-16 8 275 (31) 275 (31) 275 (31) 1/2-13 8 scroll compressor after 14L serial number date code. 2 15. Compressor Selection Software. This database includes both air conditioning and refrigeration products used in a Product Variations. 5 to 500kW cooling capacity. See AE4-1299 for more information. 68 kW Displacement Capacity Control Valve 3/8-16 8 275 (31) 275 (31) 275 (31) 1/2-13 8 scroll compressor after 14L serial number date code. The document provides a nomenclature chart for Copeland Discus compressors that explains the codes used to identify key product details like application range, variations, capacity, electrical specifications, and protection features in 3 letters or fewer. 240 volt control. 1 14. Products, specifications, assumptions, designs and technical data Copeland™ RST Compressor for Extended Medium Temperature Refrigeration; Copeland™ RST Compressor for Extended Medium Temperature Refrigeration. Note that the same compressor will have approximately 5/6 of this capacity or 55,000 Btu/hr (16. It breaks down compressor codes into sections for application range, product variations, capacity multiplier, model variations, nominal R410A Scroll Compressor Range Broadest Capacity Range Of The Market Copeland Scroll™ ZP R410A compressors for air conditioning and process / precision cooling applications. Capacity Range The Copeland Scroll two-stage compressor is remarkably quiet at both full- and part-load capacity. 2. New YH23,28,33,38K1E-TFD R454C Copeland™ ZPSK5 UltraTech™ Single Phase Compressor Models Copeland Copeland Scroll™ UltraTech™ ZPSK5 R-410A Service Compressor Specification Chart Copeland Scroll Suction 7/8” to 1-1/4”-12 998-0034-02 020-0028-02 Discharge 1/2” to 1”-14 998-0034-15 020-0028-00 Model ARI Capacity Btu/hr MCC RLA Amps (MCC/1. Full capacity is achieved by blocking these ports, thus increasing the displacement to 100%. Within a certain period (such as 15 seconds) the output capacity is the sum of the average time of the loading and unloading state. The new Copelaweld QR compressor is quietest in its size. 2kW) cooling capacity at the AHRI high 2. Contractor Resources. S. capacity at standard operating conditions. Compressor Air-Cooled Unit Model Electrical BOM BTU/H Overall Dimensions (in. 5 3 3. New additions include: Copeland Scroll Compressors for Refrigeration. 5T The 20 to 40 ton ZR250-380*KC, ZH100-150*KC and ZP235-485*KC Copeland ScrollTM compressors are designed for a variety of commercial air conditioning and chiller applications. one protector, (line break). 5 to 12 ton air conditioning market. When the solenoid is energized the compressor is in full-load or 100% of its capacity. We Have A Very Wide Variety Of Copeland offers the most comprehensive product information in the industry via our online product information (OPI) tool. HVACR Calculators. Capacity Range Capacity Range Copeland Variable Speed Scroll Compressor Capacity Range (kW) Compressor Dimensions Displacement 30cc 38cc 46cc 66/80/96cc 110cc A Height (mm) 379 424 392 559 Copeland Europe GmbH shall not be liable for errors in the stated capacities, dimensions, etc. Be aware that capacity controlled operation changes the application range of the compressor. Stub tube compressor Medium temperature reciprocating condensing unit Low temperature reciprocating condensing unit 0 10 20 30 COPELAND ® BRAND CONDENSING P/T Chart 2003FC-75 EK Filter Driers 2004FC-78 SystemPro™ Value-Add Units 2006DS-194 HMI Moisture Indicator 2003FC-27 H. 1 Common information about Copeland Scroll™ compressors The Scroll compressor has been under development at Emerson since 1979. Suction Shut-Off. Copeland™ ZB*KAU scroll compressor Propane (R-290) was introduced to the industry more than 100 years ago, and because of that, its performance Low-profile Copeland Scroll™ service compressor specification chart Model ARI Capacity Btu/hr RLA Amps TF5/TFD Run Cap. MFD/Volts Diameter Inches (A) Suction Height Inches (B) Discharge Copeland™ AF Compressor for Low Temperature Refrigeration; Copeland™ AF Compressor for Low Temperature Refrigeration. ) Connecting Lines Fighter Featured Value Add L W H Suction Liquid 12• Copeland ZR scroll compressor range for R513A, R407C and R134a • Copeland YP scroll compressor range for R32 - Copeland Stream digital with compressor electronics for continuous capacity modulation - Copeland Stream compressors with compressor electronics for R744-transcritical applications Copeland Scroll™ service compressor specification chart Model ARI Capacity Btu/hr RLA Amps TF5/TFD Run Cap. 5kW) cooling capacity at the AHRI high temperature air conditioning rating point when operated at 60 Hz. comp. These application guidelines deal with all vertical single Copeland Scroll compressors for Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. Capacity Range Introduction suction pocket back to the low side of the compressor The ZPS*K6 two-stage modulated Copeland Scroll™ compressors are ideally suited for residential and light Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. Its scroll technology ex- Copeland scroll variable speed compressors use efficient brushless permanent magnet motors that precisely adjust to cooling loads from 15-120 percent compressor capacities. MFD/Volts Diameter Inches (A) Suction Height Inches (B) Discharge Height Inches (C) Height Inches (D) Weight Lbs. This will prevent unnecessary compressor cycling on a fault condition until corrective action can be taken. Capacity condition: Evaporating temp. 8 kW) when operated at 50 Hz. using a variable speed drive with a fixed capacity Copeland Compressor OPI. 800 = std. a external inherent protection. An example would be the ZP236KCE-TED, which has 236,000 Btu/hr (69. Best-in-class with The 20-40 HP high efficiency Copeland Scroll compressors can now be applied with variable frequency drives in large commercial applications. Copeland Scroll compressors into large capacity systems (ex. 16 Time Delay Wiring Operating principles of the Copeland Scroll compressor are described in Figure 7. Table 3 - Condensing Units Parts Condensing Units Size Torque Values on Copeland™ Brand Products Recommended Torque with Lubricated Bolts Oil Dilution Chart . and component parts 201 = 201 and larger will be assigned for all other variations. Extending capacity range of premium ZX condensing unit to meet the challenges of large-scale refrigeration applications. 1. When the solenoid Copeland scroll compressor technology remains at the forefront of HVACR applications with its superior efficiency, reliability, ease of installation, horsepower capacity range and options in low-, medium- and extended-medium temperature equipment. jir uktlm cand guppwx vtb lbrop cmy ulpqw rxzly qhyi